Machine will not steer left or right

Enable switch not activated

Activate enable switch

Function not activated within the 3 seconds after
enable switch was depressed

Reactivate enable switch

Enable switch not functioning properly

Replace enable switch circuit card

Wiring on controller is damaged

Repair or replace wiring

Wiring on solenoid valve is damaged

Repair or replace wiring

Coil in solenoid is damaged

Replace coil

Bent cylinder rod

Repair or replace cylinder

Damaged steer linkage

Repair or replace steer linkage

Crossover relief valve stuck

Repair or replace crossover relief valve

Pressure setting incorrect

Reset pressure setting

Machine wanders; steering not firm

Crossover relief valve set too low or not functioning
properly

Reset, repair or replace valve as required

Steer linkages loose

Tighten linkage

Steer wheel toe-in not set properly

Adjust toe-in for 1/4 inch overall

Spindle bushings badly worn

Replace bushings

Spindle bushings to tight

Replace bushings

OSCILLATING AXLE (IF EQUIPPED)

Axle will not oscillate

Defective lockout cylinder

Repair or replace cylinder

Lockout valve sticking

Repair or replace valve

Lack of lubrication on axle pin

Lubricate pin

Lockout valve defective

Repair or replace valve

Axle will not lock

Air in lockout system

Bleed lockout system

Defective lockout valve

Repair or replace valve

Defective pressure reducing valve feeding lockout
system

Repair or replace valve

Table 3-2. Chassis Troubleshooting