Disassembly of boom sections, Disassembly of boom sections -5, Location of components - boom powertrack -5 – JLG 660SJ ANSI Service Manual User Manual

Page 141

Advertising
background image

SECTION 4 - BOOM & PLATFORM

3120718

– JLG Lift –

4-5

securing rail to the base boom section. Remove
powertrack from boom section.

4.

Remove boom assembly from machine as follows:

a. Using suitable lifting equipment, adequately

support boom assembly weight along entire
length.

HYDRAULIC LINES AND PORTS SHOULD BE CAPPED IMMEDI-
ATELY AFTER DISCONNECTING LINES TO AVOID ENTRY OF
CONTAMINANTS INTO SYSTEM.

b. Tag and disconnect hydraulic lines from tele-

scope cylinder. Use a suitable container to retain
any residual hydraulic fluid. Cap hydraulic lines
and ports.

c. Remove hardware securing the lift cylinder rod

end to the base boom section.

d. Using a suitable brass drift and hammer, remove

the lift cylinder pin from the base boom.

e. Remove hardware securing the master cylinder

rod end to the base boom section.

f. Using a suitable brass drift and hammer, remove

the master cylinder pin from the base boom.

g. Remove hardware securing the pushbar to the

turntable upright.

WHEN REMOVING PIN FROM PUSHBAR. CARE MUST BE TAKEN
NOT TO DROP THE PUSHBAR ONTO THE WIRE ROPE ADJUST-
MENT THREADS. FAILURE TO DO SO WILL RESULT IN DAMAG-
ING THREADS.

h. Using a suitable brass drift and hammer, remove

the push bar pin from the turntable upright.

i.

Remove hardware securing the boom pivot pin
to the turntable upright.

j.

Using a suitable brass drift and hammer, remove
the pivot pin from the turntable upright.

k. Using all applicable safety precautions, carefully

lift boom assembly clear of turntable and lower
to ground or suitably supported work surface.

Disassembly of Boom Sections

1.

Remove hardware securing the push bar to aft end
of the telescope cylinder, then remove pin from cyl-
inder.

2.

Remove hardware securing the cover plate on the
bottom front of the base boom section.

NOTE: Do not allow wire rope to rotate. This may damage

the wire rope.

3.

Clamp both threaded ends of wire rope to prevent
rotation. Note: Do not clamp on threads. Remove
jam nuts and nuts which secure the wire rope
adjustments to the bottom front of the base boom
section.

4.

Remove hardware securing the wire rope adjust-
ment block to aft end of the base boom section and
remove the block.

5.

Remove hardware securing the telescope cylinder
to aft end of the mid boom section.

WHEN REMOVING THE TELESCOPE CYLINDER FROM THE
BOOM, IT MAY BE NECESSARY AT SOME POINT IN ORDER TO
CLEAR ASSEMBLIES MOUNTED WITHIN THE BOOM. CARE MUST
BE TAKEN TO MOVE THE CYLINDER SLOWLY FROM THE BOOM.
DAMAGE TO COMPONENTS MAY RESULT FROM FORCIBLE
IMPACT WITH THESE ASSEMBLIES.

6.

Remove bolts securing wire rope attach bar to top of
fly boom section.

7.

Pull the telescope cylinder and wire ropes partially
from aft end of the base boom section; secure the
cylinder with a suitable sling and lifting device at
approximately the center of gravity.

Figure 4-6. Location of Components - Boom Powertrack

Advertising