JLG 660SJ ANSI Service Manual User Manual

Page 241

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3120718

– JLG Lift –

6-27

3/4

Flash code 3/4 indicates a driver problem on a platform valve block
valve driver. All driver faults are detected in a similar manner. Open cir-
cuit faults are detected when the analog feedback reads too high and
the output is commanded off. Short to ground is detected when the
analog feedback reads low and the output is commanded on. Short to
battery is detected when the analog feedback reads Vbat and the out-
put is commanded off. Not reported during 2 second power-up.

6

BASKET UP SHORT TO BAT-
TERY

BASKET UP SHORT TO
GROUND

BASKET UP OPEN CIRCUIT

BASKET UP SHORT TO
BATTERY OR OPEN CIRCUIT

Only occurs on machines with electronic basket leveling

BASKET DOWN SHORT TO
BATTERY

BASKET DOWN SHORT TO
GROUND

bASKET DOWN OPEN CIR-
CUIT

BASKET DOWN SHORT TO
BATTERY OR OPEN CIRCUIT

Only occurs on machines with electronic basket leveling.

BASKET LEFT SHORT TO
BATTERY

BASKER LEFT SHORT TO
GROUND

BASKET LEFT OPEN CIRCUIT

BASKET RIGHT SHORT TO
BATTERY

BASKET RIGHT SHORT TO
GROUND

BASKET RIGHT OPEN CIR-
CUIT

JIB UP SHORT TO BATTERY

JIB UP SHORT TO GROUND

JIB UP OPEN CIRCUIT

JIB DOWN SHORT TO BAT-
TERY

JIB DOWN SHORT TO
GROUND

JIB DOWN OPEN CIRCUIT

JIB LEFT SHORT TO BAT-
TERY

JIB LEFT SHORT TO
GROUND

Table 6-3. Help Fault Codes, Displayed Faults, and Descriptions - S/N 66937 to Present

Fault Flash

Code

Communicated (Displayed on

Analyzer) Fault

Description

Priority

Advertising