SECTION 1 - SPECIFICATIONS

1-14

– JLG Lift –

3120718

NOTES:

KEY TO LUBRICANTS

* Machines after S/N 38047 will have composite bushings and no grease fittings.

Lubrication intervals are based on machine operation under normal
conditions. For machines used in multi shift operations and/or
exposed to hostile environments or conditions, lubrication frequen-
cies must be increased accordingly.

** When changing oil in the Deutz oil cooled engine, drain both the crankcase and
the cooler. When refilling it is acceptable to overfill the crankcase (16 qts., capac-
ity of both crankcase and cooler combined). Start engine, allow the engine to run
until the thermostat opens (approximately 221 degrees F) cooler will fill up within
minutes; shut down and wait for approximately two minutes. Check oil level, fill oil
to max marking on the dipstick.

EO

EPGL

HO

MPG

Engine Oil
Extreme Pressure Gear Lube
Hydraulic Fluid (Mobil #424 or equivalent)
Multi-Purpose Grease

Table 1-12. Lubrication Chart - S Models

Components

Number/Type

Lube Points

Capacity

Lube

Interval

Hours

Comments

3 Months

150 hrs

6 Months

300 hrs

1 Year

600 hrs

2 Years

1200 hrs

Advertising