SECTION 3 - CHASSIS & TURNTABLE

3120718

– JLG Lift –

3-81

DTC 362 - Megajector voltage supply low.

a. Voltage - Check battery voltage. If the voltage at

the battery is less than 9.5 volts:

The battery is faulty

or

The charging system is faulty

or

The Megajector is faulty.

DTC 363 - Megajector Internal Actuator Fault Detection.

a. Connections - Check power, ground, and CAN

circuits at the Megajector in addition to all elec-
trical connections. Repair as necessary and
retest.

b. Megajector - Megajector has an internal failure.

Contact JLG Industries for further assistance.

DTC 364 - Megajector Internal Circuitry Fault Detection.

a. Connections - Check power, ground, and CAN

circuits at the Megajector in addition to all elec-
trical connections. Repair as necessary and
retest.

b. Megajector - Megajector has an internal failure.

Contact JLG Industries for further assistance.

DTC 365 - Megajector Internal Comm Fault Detection.

a. Connections - Check power, ground, and CAN

circuits at the Megajector in addition to all elec-
trical connections. Repair as necessary and
retest.

Megajector - Megajector has an internal failure. Contact
JLG Industries for further assistance.