JLG 660SJ ANSI Service Manual User Manual

Page 247

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3120718

– JLG Lift –

6-33

11
(Gen Set/ Welder)

0

1

2

No Generator Installed

Belt Driven

Hydraulic Driven

0

12
(Head and Tail Lights)

0

1

No Head and Tail Lights Installed

Yes

0

13
(Broken Cable Switch)

0

1

No Broken Cable Switch Installed

Yes

0

14
(Load Sensor)

0

1

2

3

4

No Load Sensor installed - (DOM - STD)

Functions in Creep, Overload Lamp Lit, Platform Alarm Beeps (5 sec. ON, 2 sec OFF)

All functions cutout, flash overload light (500mS on, 500mS off), Platform Alarm beeps (5
sec ON, 2 sec OFF) - (CE - STD)

All functions cutout, Overload Lamp Lit, Platform Alarm Beeps (5 sec ON, 2 sec OFF)

Special = Functions in Creep, Overload Lamp Lit, Platform Alarm Beeps (5 sec ON, 2 sec
OFF), disables Upper Telescope Out & Upper Lift Up

0

15*
(Load Sensor)

(*Only visible if Load Sensor
Menu selection is not 0)

0

1

1 on rotator - Use the on-board load sensor for all models except those which use the Lev-
eling Platform Module

4 under platform - Use the EIM

0

16
(Function
Cutout)

0

1

2

3

No Drive Cutout - (DOM - STD)

Boom function cutout while driving above elevation. (CE - STD)

Drive Cutout above elevation

Drive Cutout above elevation and tilted

0

17
(Ground Alarm)

0

1

2

3

No ground alarm installed.

Travel alarm- Sounds when the drive function is active.

Option

Descent Alarm- Sounds when either lift down is active.

Option

Motion alarm- Sounds when any function is active.

Option

0

18
(Tower Prox Switches)

0

1

No Tower Prox Switches Installed

Tower Prox Switches Installed - 450A,510, 600A, 740AJ, 800A

0

Table 6-4. Machine Configuration Programming Information

Configuration Digit

Number

Description

Default Number

Advertising