Machine configuration programming information -31 – JLG 660SJ ANSI Service Manual User Manual

Page 245

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3120718

– JLG Lift –

6-31

Table 6-4. Machine Configuration Programming Information

Configuration Digit

Number

Description

Default Number

1
(Model #)

1
2
3
4
5
6
7
8
9

10
11

400
450
600
601
800A
800S
1350SJP
1200SJP
600C
510A
740A

1

2
(Engine)

1

2

3

4

5

6

9

10

11

12

Ford LRG425 EFI Gas

Ford LRG425 EFI Gas with dual fuel

Deutz F4M1011F Diesel

Deutz F3M1011F Diesel

CAT 3024C Diesel

CAT 3044C Diesel

Deutz F4M2011 Diesel (Tier 2)

Deutz F3M2011 Diesel (Tier 2)

Ford LRG425 Gas (Tier 2)

Ford LRG425 Dual Fuel (Tier 2)

1

3
(Glow Plugs)

0

1

2

3

4

5

6

7

8

9

No Glow Plugs Installed

Automatic Pre-Glow time determined by Ambient Air Temperature; engine start can be
attempted at any time during Pre-Glow.

Automatic Pre-Glow time determined by Ambient Air Temperature; engine start is not
permitted until Pre-Glow is finished.

5 seconds of Pre-Glow

10 seconds of Pre-Glow

20 seconds of Pre-Glow

30 seconds of Pre-Glow

40 seconds of Pre-Glow

50 seconds of Pre-Glow

60 seconds of Pre-Glow

0