6.8 MACHINE PERSONALITY SETTINGS

NOTE: Personality settings can be adjusted within the

adjustment range in order to achieve optimum
machine performance.

Table 6-1. Personality Ranges/Defaults

FUNCTION

PERSONALITY

RANGE

DEFAULTS - 600S

DEFAULTS - 600A

DRIVE

ACCELeration

0.1s to 5.0s

2.0

2.0

DECELeration

0.1s to 3.0s

2.0

2.0

Forward MINimum speed

0 to 35%

4

4

Forward MAXimum speed

0 to 100%

35

35

REVerse MINimum speed

0 to 35%

4

4

REVerse MAXimum speed

0 to 100%

35

22

ELEVATED MAXimum speed

0 to 50%

15

10

CREEP MAXimum speed

0 to 50%

25

25

Engine RPM

800 to 2900

1800

1800

TOWER LIFT

ACCELeration

0.1 to 5.0

N/A

1.0

DECELeration

0.1 to 3.0

N/A

0.5

MlNimum UP speed

0 to 60%

N/A

50

MAXimum UP speed

0 to 100%

N/A

100

MINimum DOWN speed

0 to 60%

N/A

50

MAXimum DOWN speed

0 to 100%

N/A

100

Engine RPM

800 to 2900

N/A

1800

UPPER LIFT

ACCELeration

0.1 to 5.0

2.0

2.0

DECELeration

0.1 to 3.0

1.0

0.7

MlNimum UP speed

0 to 60%

40

30

MAXimum UP speed

0 to 100%

80

55

CREEP Maximum UP speed

0 to 65%

55

55

MINimum DOWN speed

0 to 60%

40

40

MAXimum DOWN speed

0 to 100%

70

65

CREEP maximum DOWN speed

0 to 75%

55

55

Engine RPM

800 to 2900

1800

1800