SECTION 2 - PROCEDURES

3121801

– JLG Lift –

2-29

e. The Ground Control Box, as mounted on the

machine, does not allow the tilt sensor to be
level.

For the following troubleshooting steps, a bubble level
(smaller is better) will be needed and the machine must
be on a level surface:

1. On the Analyzer, go to Diagnostics/System and read

the tilt angle. If either angle reports +20.0°, there is
an electrical/electronic failure (tilt sensor, control
board, electrical connections).

a. Open the Ground Control Box.
b. Disconnect the sensor and clean any corrosion

off of the tilt sensor and control board connec-
tions.

c. Reassemble and test. If fault persists, replace tilt

sensor.

2. If the Analyzer displays angles other than +20.0°,

attempt to calibrate. If machine will not calibrate,
note the reason displayed on Analyzer:

a. SENSOR FAILURE – tilt sensor internal fre-

quency is out of range (replace sensor).

b. NOT LEVEL - tilt sensor has either developed an

offset or it is to unlevel as mounted on the
machine.

Joystick Calibration

(Software 1.5 and Higher and Higher)

Using the Analyzer, in Access Level 1, go to MENU: CALI-
BRATION: JOYSTICK and press ENTER.

1. Following the analyzer screen prompts:

a. Move the Joystick FORWARD and press ENTER.
b. Allow Joystick to be in CENTER position and

press ENTER.

c. Move the Joytstick REVERSE and press ENTER.

2. CAL COMPLETE or CAL FAILED will display on the

analyzer.

3. Possible reasons if calibration failed:

a. The forward position must be a lower voltage

than reverse position.

b. The difference between center and forward &

center and reverse must be atleast 1V.