Adjusting parameters using the hand held analyzer, Machine setup – JLG 260MRT Service Manual User Manual

Page 55

Advertising
background image

SECTION 2 - PROCEDURES

3121801

– JLG Lift –

2-33

Adjusting Parameters Using the Hand Held
Analyzer

Once you have gained access to level 1, and a personality
item is selected, press the UP or DOWN arrow keys to
adjust its value, for example:

PERSONALITIES:
DRIVE ACCEL 4.0s

There will be a minimum and maximum for the value to
ensure efficient operation. The Value will not increase if
the UP arrow is pressed when at the maximum value nor
will the value decrease if the DOWN arrow is pressed and
the value is at the minimum value for any particular per-
sonality. If the value does not change when pressing the
up and down arrows, check the access level to ensure
you are at access level 1.

Machine Setup

When a machine digit item is selected, press the UP or
DOWN arrow keys to adjust its value, for example:

FAILURE TO MAKE THE PROPER SETTINGS FOR THE PARTICU-
LAR MACHINE CAN RESULT IN IMPROPER OPERATION.

CHANGING THESE SETTINGS MAY ADVERSELY AFFECT THE
PERFORMANCE OF THE MACHINE.

LEVELING JACKS:
1=YES

The effect of the machine digit value is displayed along
with its value. The above display would be selected if the
machine was equipped with a ground alarm and you
wanted it to sound when driving. There are certain set-
tings allowed to install optional features or select the
machine model.

When selecting the machine model to match the size of
the machine, the personality settings will return to default
settings.

NOTE: Refer to the appropriate Machine Personality Set-

tings Table, and the Machine Setup Table in the JLG
Service Manual for the recommended factory set-
tings.

Password 33271 will give you access to level 1,
which will permit you to change all machine person-
ality settings.

IT IS A GOOD PRACTICE TO AVOID PRESSURE-WASHING ELEC-
TRICAL/ELECTRONIC COMPONENTS. SHOULD PRESSURE-
WASHING BE UTILIZED TO WASH AREAS CONTAINING ELECTRI-
CAL/ELECTRONIC COMPONENTS, JLG INDUSTRIES, INC. REC-
OMMENDS A MAXIMUM PRESSURE OF 750 PSI (52 BAR) AT A
MINIMUM DISTANCE OF 12 INCHES (30.5 CM) AWAY FROM THESE
COMPONENTS. IF ELECTRICAL/ELECTRONIC COMPONENTS
ARE SPRAYED, SPRAYING MUST NOT BE DIRECT AND BE FOR
BRIEF TIME PERIODS TO AVOID HEAVY SATURATION.

PERSONALITIES:
DRIVE ACCEL 4.0s

l evel i n g j ack s:
1=y es

Advertising