21 machine model adjustment, Machine model adjustment -39 – JLG 260MRT Service Manual User Manual

Page 62

Advertising
background image

SECTION 2 - PROCEDURES

2-40

– JLG Lift –

3121801

2.21 MACHINE MODEL ADJUSTMENT

Table 2-11. Machine Model Adjustment

Adjustment

Adjustment range

Default Values - Gas

Default Values - Diesel

DRIVE

ACCEL

1.0 to 5.0 sec

4

4

DECEL

1.0 to 5.0 sec

2

2

FWD MIN

0 to 100%

21

21

FWD MAX

0 to 100%

52

52

FWD ELEV

0 to 35%

30

30

REV MIN

0 to 100%

21

21

REV MAX

0 to 100%

52

52

REV ELEV

0 to 35%

30

30

LO MAX

35 to 65%

50

50

ENGINE SPD

2800 to 3800 RPM

3600

3000

GAIN

0 to 999

180

50

DROOP

0 to 999

200

250

STABILITY

0 to 999

170

80

LIFT

ACCEL

0.2 TO 5.0

3

3

DECEL

0.2 TO 5.0

0.5

0.5

UP MIN ENG

1400 TO 2200 RPM

2000

1800

UP MAX ENG

2600 to 3600 RPM

3600

3000

LO MAX

35 to 55%

50

50

GAIN

0 to 999

150

5

DROOP

0 to 999

220

200

STABILITY

0 to 999

125

90

IDLE

ENGINE SPEED

1200 TO 1500 rpm

1500

1500

GAIN

0 to 999

150

10

DROOP

0 to 999

250

90

STABILITY

0 to 999

100

130

MIN ACT

0 T0 100%

19

18

MAX ACT L/D

0 T0 100%

60

100

MAX ACT IDLE

0 T0 100%

55

55

CUT ACT

200 To 2800 RPM

500

500

GEN ENG SPD

2000 To 3600 RPM

3000

3000