Ground control station, Ground control station -2 – JLG E300 Operator Manual User Manual

Page 32

Advertising
background image

SECTION 3 - MACHINE CONTROLS AND INDICATORS

3-2

– JLG Lift –

3121252

TO AVOID SERIOUS INJURY, DO NOT OPERATE MACHINE IF ANY CON-
TROL LEVERS OR TOGGLE SWITCHES CONTROLLING PLATFORM
MOVEMENT DO NOT RETURN TO THE OFF POSITION WHEN RELEASED.

Ground Control Station

(See Figure 3-1. and Figure 3-2. )

NOTE: When machine is shut down the Platform/Ground Select

switch and Emergency Stop must be positioned to OFF.

NOTE: When Power/Emergency Stop Switch is in the on position

and motor is not running, an alarm will sound, indicating
power is on.

NOTE: The Function Enable switch must be held

down in order to operate Boom Telescope,
Lower Lift, Swing, Main Lift, Jib Lift, Platform
Level Override, and Platform Rotate functions.

1. Battery Charge Status

Three LED lights indicate charge status of battery.
Green; indicates 100% charged. Yellow; indicates
charger on. Red; indicates abnormal battery condition.

2. Function Enable

The enable switch must be held "DOWN" to enable all
boom controls when the machine power is on.

3. Main Boom Lift

Provides raising/lowering of the main boom when posi-
tioning up or down.

4. Lower Boom Lift

Provides raising and lowering of the upright and lower
booms.

5. Swing

Provides 350 degrees non-continuous turntable rotation.
To activate SWING, position switch to LEFT or RIGHT.

Advertising