5 lubrication, Deutz f4l912 engine, Lubrication -3 – JLG 110HX Service Manual User Manual

Page 15: Deutz f4l912 engine -3, Hydraulic oil -3

Advertising
background image

SECTION 1 - SPECIFICATIONS

3120864

– JLG Lift –

1-3

1.5

LUBRICATION

Deutz F4L912 Engine

Single Viscosity Oils (CD-SE, CD-SF).

Multi-Viscosity Oils (CD-SE, CD-SF).

* This viscosity can be used at colder temperatures only
with engine oil preheating.

NOTE: Crankcase oil should meet one of the following API

classification grades: SE/CC, SE/CD, SF/CC, SF/
CD.

NOTE: Hydraulic oils must have anti-wear qualities at least

to API Service Classification GL-3, and sufficient
chemical stability for mobile hydraulic system ser-
vice. JLG Industries recommends Mobilfluid 424
hydraulic oil, which has an SAE viscosity index of
152.

NOTE: When temperatures remain consistently below -7

degrees C., JLG Industries recommends the use of
Mobil DTE11.

NOTE: Aside from JLG recommendations, it is not advisable

to mix oils of different brands or types, as they may
not contain the same required additives or be of
comparable viscosities. If use of hydraulic oil other
than Mobilfluid 424 is desired, contact JLG Indus-
tries for proper recommendations.

Some machines may be specially equipped with Mobil
EAL224H biodegradable and non-toxic hydraulic oil. This
oil is vegetable oil based and possesses the same anti-
wear and rust protection characteristics as mineral oils,
but will not adversely affect ground water or the environ-
ment when spilled or leaked in small amounts. Mobil
EAL224H has a viscosity of 34 cST at 40° C and a viscosity
index of 213. The operating range of this oil is -18° C to
+83° C.

IT IS RECOMMENDED THAT MOBIL EAL224H HYDRAULIC OIL BE
STORED ABOVE FREEZING (0°C) AS THE OIL MAY APPEAR
CLOUDY AFTER EXPOSURE TO LOW TEMPERATURES FOR
EXTENDED PERIODS OF TIME. THE CLOUDINESS WILL DISAPPEAR
WHEN THE OIL IS WARMED TO AT LEAST 10°C AND AGITATED. DO
NOT ATTEMPT TO "THIN" THE OIL WITH NO.2 DIESEL FUEL. FOR
BEST RESULTS, STORE THE OIL ABOVE FREEZING.

NOTE: Accidentally mixing Mobil EAL224H hydraulic oil with

other mineral oils will cause no loss of performance
characteristics. However, biodegradability may be
reduced and toxicity may be increased, depending
on the oil and level of contamination.

When Outside Temp is

Consistently

Use SAE Viscosity Number

-29° C to -4° C

*10W

-10° C to +10° C

20W-20

+4° C to +30° C

30

Above +24° C

40

When Outside Temp is

Consistently

Use SAE Viscosity Number

-40° C to +24° C

*5W-20 (Synthetic)

-21° C to +21° C

10W-30

-21° C to +30° C

10W-40

-10° C to +24° C

15W-30

Above -10° C

15W-40

Table 1-3.Hydraulic Oil

Hydraulic System

Operating Temperature

Range

SAE Viscosity Grade

-18° C to -5° C

10W

-18° C to +100° C

10W-20, 10W-30

+10° C to +99° C

20W-20

Advertising