IP Address Retrieval

Take the following steps to retrieve the

IP address:

2N

®

Helios IP Safety

Connect (or, if connected, disconnect and reconnect)

to

2N

®

Helios IP Safety

the power supply.

Wait for the second sound signal

.

Press the quick dial button 5 times.
2N

®

Helios IP Safety will read its IP address.

If the address is 0.0.0.0, it means that the intercom has not obtained the IP
address from the DHCP server.

Switching between Static and Dynamic IP Address

Connect

to the power supply (or, disconnect and

2N

®

Helios IP Safety

reconnect it if already connected).

Wait for the first acoustic signal

.

Press

button 15 times.

the quick dial

The acoustic signal

indicates mode switching.

Wait until the device is restarted automatically.

Note

Be sure to press the button sequence within thirty seconds after the
sound signal for security reasons. Up to 2 s intervals are allowed between
the presses.