Electric lock connection, Tamper switch connection, Device resetting – 2N Helios IP Uni User Manual

Page 16

Advertising
background image

16

2N TELEKOMUNIKACE a.s., www.2n.cz

®

DC power source dimensioned to current intake of 1A at least (Part No. 91341481E) to
ensure a reliable function of your device.

PoE Supply

2N

®

Helios IP Uni is compatible with the PoE 802.3af (Class 0 – 12.95W) technology

and can be supplied directly from the LAN via compatible network elements. If your
LAN in incompatible, insert the PoE injector, Part No. 91758100E, between 2N

®

Helios

and the nearest network element.

IP Uni

Electric Lock Connection

2N

®

Helios IP Uni is equipped with an electrically isolated relay switch with NO and

NC contacts (terminal block X17) and 12V/700mA switched output (terminal block
X18), to which a standard electric lock or another compatible electrical appliance can
be connected.

Tamper Switch Connection

2N

®

Helios IP Uni is equipped with a tamper switch for detection of unauthorized

penetration into the device. After correct and complete installation of the device the
tamper switch is closed. Tamper switch opens immediately when the front panel is
removed. Tamper switch contacts are available on terminal block X18.

Device Resetting

2N

®

Helios IP Uni is equipped with a RESET button. Push the button for more than

10s to reset the factory default values, deleting all the data stored in the device. Push
the button shortly (< 1s) to restart the device without changing its configuration.