ADS-TEC RAC2000 User Manual User Manual

Page 18

Advertising
background image

RAC2000 series

17

© ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen

4.2.2 Status display activities when resetting to default settings 

By using the default setting button on the rear of the device, the RAC2000 can be reset to the default settings 
regardless of the configuration. 

The default setting button must be pushed, and the device then be switched on, in order to reset the device to 
the default settings. The default setting button must be pushed for approx. 20 seconds. As soon as both HOST 
LEDs flash, you can release the button. No HOST cable is connected in this example. By means of the following 
diagram, the correct factory default process can be traced by watching the flashing frequency of the LEDs. 

WLAN (1) / (2) 

Signal

 

Action

 

Left LED Link 

 

Device is searching for available WLAN 
networks. 

 

 

HOST 

Signal

 

Action

 

Left LED Link 

 

 

LEDs blink twice briefly 

Rechte LED Link 

 

 

LEDs blink twice briefly 

Lft LED ACT 

LED turns out 

Right LED ACT 

LED turns out 

 

 

POWER 

Signal

 

Action

 

 

 

The device is supplied with power via 
Power and is ready 

 

 

Advertising