8 adjustments, Mechanical adjustments – Brady PAM 3000 User Manual

Page 31

Advertising
background image

31

Printer-Applicator-System PAM 3000

8 Adjustments

All supplied label applicators have passed a previous run at the factory. Therefore, the basic

adjustments which are necessary for the operation of the device have been carried out.

It may be useful to do some more fine tuning when the applicator is installed. This refers

mainly to mechanical parameters, which are depending on the format of the labels as well as

some special settings for the type of operation.

Mechanical Adjustments

Adjusting the Level of the Lift Cylinder Unit

There are three screws at the front side of the applicator to adjust the level of the cylinder unit.

1. Loosen the two screws (1) at the carrier plate of the applicator. But they may not be

removed.

2. Move the whole unit within the longish holes (2) by screwing the screw (3).

The pad has to be located slightly above the dispense table of the printer.

3. Tighten the screws (1).

Fig. 8a

Level adjustment

2

1

3

1

2

Advertising