Printer-Applicator-System PAM 3000

C-2

Fig. C-5 Interface cable with 9 pin computer connector for RS-232 with protocol

"RTS/CTS" or "XON/XOFF"

Fig. C-4 Interface cable with 25 pin computer connector for RS-232 with protocol

"RTS/CTS" or "XON/XOFF"

PC

Printer

25 pin connector

25 pin plug

1

1

2

3

3

2

4

5

5

4

7

7

6

8

20

PC

Printer

9 pin connector

25 pin plug

2

2

3

3

5

7

7

5

8

4

1

4

6

Interface Cable for RS-422 / RS-485

To control the printer by RS-422/ RS-485 interface, only the signals TDATA+, TDATA-,

RDATA+, and RDATA- are necessary.

Check the pin assignment for the interface of your computer, and use the pin assignment of

the printer as shown in table C-1 to obtain a suitable cable. The connectors of TDATA+ and

RDATA+ as well as TDATA- and RDATA- at the plug-in-connection of the cable must be

united. If there is a very large transfer distance a termination of the cables is recommended.

PC

Printer

2

2

3

3

5

7

8

20

1

4

4

5

6

Fig. C-3 Interface cable with 9 pin computer connector for RS-232 with protocol

" ---" or "XON/XOFF"

9 pin connector

25 pin plug