Wiring Information for Solenoid


WARNING!!!

GATES MUST NOT OPEN WHEN THE LIFT IS IN OPERATION OR

WHEN THE PLATFORM IS NOT PRESENT.

SHOULD THIS CONDITION EXIST, THE INTERLOCK IS NOT

FUNCTIONING PROPERLY DUE TO INCORRECT INSTALLATION

OR DAMAGE. THIS CONDITION MUST BE CORRECTED

IMMEDIATELY. FAILURE TO CORRECT THIS CONDITION MAY

RESULT IN SERIOUS INJURY OR DEATH.


CAUTION!!!

ALL CONNECTIONS MUST BE MADE BY A QUALIFIED

ELECTRICIAN, AND OPERATION MUST BE VERIFIED.


8.
The solenoid requires 24 VOLT DC power. Application of other power sources WILL RESULT IN
SEVERE DAMAGE TO THE INTERLOCK.


9. The DC power is obtained through the use of a Rectifier which is supplied in the electrical control
enclosure.

10. The proper solenoid connections for 24 volt DC operation are to connect the RED and WHITE
leads from the solenoid to the correct terminals in the electrical control enclosure.

11. The Black and Blue leads of the solenoid MUST be wired together.