It1000-ab, Troubleshooting, 17 of 38 – BAND-IT IT1000-AB 1/4 Tie-Lok Tool User Manual
Page 17: 1/4” tie-lok, Tool
Document # I17791 Rev H
© Copyright
BAND-IT-IDEX, Inc. 2009
All rights reserved
www.BAND-IT-IDEX.com
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver, CO 80216-0307 USA
P: 1-800-525-0758 F: 1-800-624-3925
17 of 38
IT1000-AB
1/4” Tie-Lok
®
Tool
Tool fails to cut off clamp tail:
• The Inlet Air Pressure may be low. Check air supply to Air Controller Module. Cut-off
Pressure Gauge should indicate 100 -110 PSI (690-760 kPa). See pages 4-6 for air supply
requirements.
• The scrap clamp tail from the previous clamp may not have been removed. Press the Reset
Button to release the tension on the clamp and remove the scrap clamp tail.
• The Cutter Blade or Knife may be worn. See below for Cutter Blade inspection and
replacement.
• Note: The Flip Cover Tightening Screw and Head Screws are factory tensioned and will
need to have thread locking compound reapplied and be re-tightened after the quick release
pins are reinstalled upon completion of maintenance.
2. Remove Flip
Cover and
Tension Block
Assembly for
cleaning and
lubrication.
3. Remove the Cutter
Blade Pin and Cutter
Blade. The Cutter
Blade has two working
edges and can be
rotated 180
° to use the
second edge prior to
replacement.
4. When installing
the Cutter Blade
Pin, use a small
screwdriver to
push the front
gripper toward the
back of the tool.
1. Loosen the Flip
Cover Tightening
Screw and Head
Screws (see note
above) to remove both
Quick Release Pins as
shown.
Cutter Blade Inspection and Replacement:
Front
Gripper
Cutter
Blade Pin
Troubleshooting