Fault finding – Carbolite ABA 7/35B User Manual

Page 66

Advertising
background image

66

MF60

– 1.04

25

Fault Finding

Disconnect the equipment from the supply before carrying out any internal
investigation.

The Furnace Main Chamber or After-burner Does Not Heat
The Heat
lamp/s is/are
On

► The heating elements may

have failed

►

Check also that the SSRs are
working correctly

The Heat
lamp/s
is/are Off

► The controller shows a

zero temperature

►

The thermocouple may have
broken or may have a
wiring fault

► The controller shows a

low temperature

►

The door switch may be faulty

►

A relay may be faulty

►

The SSR could be failing to
switch on due to
internal failure, faulty logic
wiring from the
controller, or faulty controller

► The controller is not

illuminated

►

Check the supply fuses and
any fuses
in the control compartment

►

The controller may be faulty
or not
receiving a supply due to a
faulty
switch or a wiring fault

The Main Chamber or After-burner is Slow to Heat Up

One of the
Heat lamps
does
not light

►

A fuse may have
blown

►

Check the Supply fuses

The Heat
lamps all light
up

► An element may

have failed

►

Check that the SSRs are
working correctly

Furnace Overheats

The heater
lamps never
turn off

►

The controller
shows a very high
temperature

►

The controller may be faulty

►

The controller
shows a low
temperature

►

The thermocouple may
have been shorted
out or may have been
moved out of the
heating chamber

►

The thermocouple may be
mounted the
wrong way round

►

The controller may be faulty

Continued

Advertising