Troubleshooting, Troubleshooting guide - electrical – Bosch 4405 User Manual

Page 33

Advertising
background image

33.

Troubleshooting

Troubleshooting Guide - Electrical

PROBLEM

Brake does not stop blade in
about 5 seconds

Motor does not start.

Flash of light from motor end-
cap when switch is released.

CAUSE

1. Brushes not seated or lightly

sticking or worn.

2. Motor overheated from use

of dull blade/too heavy of a
blade, not recommended
accessory or rapid on/off
cycling.

3. Blade bolt loose.

4. Other

1. Check that unit is plugged in.

2. Power source fuse or

time delay fuse.

3. Brushes worn.

4. Other.

1. Normal - brake

working properly.

CORRECTIVE ACTION

• Inspect/clean or replace

brushes (see Maintenance
Section).

Use sharp blade.

• Use a recommended blade.
• Let saw cool down.

Tighten blade bolt.

Authorized service

Plug unit in. Use different
outlet.

15-Amp time delay fuse or
circuit breaker.

See Brush Replacement in
the Maintenance and Lubri-
cation section.

Authorized service.

None required.

Note: To find an authorized service center,

call 1-877-BOSCH99 (1-877-267-2499)

or visit www.boschtools.com.

Advertising