Troubleshooting – CHAMPION EUCC Series User Manual

Page 28

Advertising
background image

20

Troubleshooting

Troubleshooting

CONDITION

CAUSE

SOLUTION

Low final rinse temperature

Low incoming water temperature .......

Raise incoming water temperature

140°F for 40°F rise booster

110°F for 70°FS rise booster

180°F without booster

Defective thermometer ........................

Check or replace

Defective thermostat ...........................

Recalibrate or replace

High limit thermostat tripped ..............

Reset or replace

Low steam pressure.............................

Check steam supply pressure

Poor washing results

Detergent dispenser not operating ......

Contact the chemical supplier

Detergent supplied not strong

enough .................................................

Contact the chemical supplier

Wash water temperature too low

See Condition “Wash/Rinse tank

water temperature too low”

Spray pipes clogged ............................

Clean

Improperly scrapped dishes ................

Check scrapping procedures

Ware improperly loaded on

conveyor ..............................................

Stagger ware on belt

Maintenance not performed

as required ...........................................

See Maintenance Schedule

Electric elements/steam coils have .....

Clean and delime

lime build-up .......................................

Contact the chemical supplier

Poor drying results

Excessive humidity in

warewashing area ................................

Check vent dampers and exhaust

Improperly stacked dishes

after washing .......................................

Check unloading procedures

Insufficient rinse-aid ...........................

Contact chemical supplier

Final rinse temperature

See Condition “Final Rinse temperature

too low ................................................

too low”