28

19. Remove the shipping braces from

the sections.

20. Identify the location of piping

between the sections.

21. Check the height of each section

and determine which section is the

highest due to floor variations.

22. Set the "C" section and adjust to its

minimum height.

23. Level the "C" section side to side

and front to back in several places

with a bubble level.

24. The remaining sections are leveled

in relation to "C" section.

Do not adjust the "C" section

too high.

25. Apply a 1/4" bead of FOOD

GRADE sealant to the foam

gaskets on each section.

26. Move the next section close to

the "C". Adjust the feet of this

section to align the 20 bolt holes

around the hood.

27. Slide the connecting hoses and

clamps on drain pipes and cross-

flow pipes. Do not tighten

at this time.

28. Level each section side to side

and front to back making sure

the section connecting bolt holes

align.

Installation Instructions _______

Section Assembly:

Section Assembly

ApprOved seAlAnT wAs sUpplIed In

The hArdwAre kIT.

dO nOT sUBsTITUTe AnOTher

TYpe OF seAlAnT.