ElmoMC Gold Line Digital Servo Drives-Gold Cello User Manual

Page 25

Advertising
background image

Gold Cello Installation Guide

MAN-G-CELIG (Ver. 1.201)

||Motor Power Connector Pinouts (J9)|

www.elmomc.com

25

Table of Contents

Figure 9: Brushless Motor Power Connection Diagram

Figure 10: DC Brushed Motor Power Connection Diagram

To power the drive, connect the M1, M2, M3, and PE pins on the Gold Cello. The phase connection
is arbitrary as Elmo Application Studio (EASII) will establish the proper commutation automatically
during setup. When tuning a number of drives, you can copy the setup file to the other drives and
thus avoid tuning each drive separately. In this case the motor-phase order must be the same as on
the first drive.

For best immunity, it is highly recommended to use a 4-wire shielded (not twisted) cable for

the motor connection. The gauge is determined by the actual current consumption of the

motor.

Connect the cable shield to the closest ground connection at the motor end.

For better EMI performance, the shield should be connected to Protective Earth (PE

terminal). Connect the Braid wire to the PE terminal on the motor connector.

Ensure that the motor chassis is properly grounded.

Advertising