Gold Cello Installation Guide

MAN-G-CELIG (Ver. 1.201)

||Auxiliary Power (J10)(optional)|

www.elmomc.com

27

Table of Contents

Figure 11: Main Power Supply Connection Diagram (no Auxiliary Supply)

6.4. Auxiliary Power (J10)(optional)

Signal (J10) Function

Cable

VL+

Auxiliary Supply Input

DC Power

PR

Auxiliary Supply Return

DC Power

2-Pin Phoenix 3.81 mm Pitch

2-Pin Phoenix Plug-in Connector

Table 6: Aux. Power Connector – Pin Assignments

Caution: Power from the Gold Cello to the motor must come from the Main
Supply and not from the Auxiliary Supply.

Note:

The source of the Auxiliary Supply must be isolated.

Connect the VL and PR pins on the Gold Cello in the manner described below.

Power to the Auxiliary Supply can be provided by a separate Auxiliary Supply.