User i/os, Digital inputs (j1) – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Hornet User Manual
Page 55

Gold Hornet Installation Guide (EtherCAT and CAN)
Installation
MAN-G-HORIG-E (Ver. 1.007)
55
4.10. User I/Os
The Gold Hornet has six programmable digital inputs (J1), four digital outputs (J1) and one
analog input (J2).
4.10.1. Digital Inputs (J1)
Each of the pins below can function as an independent input. The inputs conform to the TTL
level.
Pin (J1) Signal
Function
3
INRET1-6
Programmable inputs 1 - 6 return
4
IN1
High speed programmable input 1
(event capture, home, general purpose, RLS, FLS, INH)
5
IN2
High speed programmable input 2
(event capture, home, general purpose, RLS, FLS, INH)
6
IN3
High speed programmable input 3
(event capture, home, general purpose, RLS, FLS, INH)
7
IN4
High speed programmable input 4
(event capture, home, general purpose, RLS, FLS, INH)
8
IN5
High speed programmable input 5
(event capture, home, general purpose, RLS, FLS, INH)
9
IN6
High speed programmable input 6
(event capture, home, general purpose, RLS, FLS, INH)
Table 17: Digital Input Pin Assignments