5.2. Environmental Conditions
Feature
Operation Conditions
Range
Ambient
Temperature
Range
Non-operating conditions
-50 °C to +100 °C (-58 °F to 212 °F)
Operating conditions
-40 °C to +70 °C (-40 °F to 160 °F)
Temperature
Shock
Non-operating conditions
-40 °C to +70 °C (-40 °F to 160 °F)
within 3 min.
Altitude
Non-operating conditions
Unlimited
Operating conditions
-400 m to 12,000 m (-1312 to 39370 feet)
Maximum
Humidity
Non-operating conditions
Up to 95% relative humidity non-
condensing at 35 °C (95 °F)
Operating conditions
Up to 95% relative humidity non-
condensing at 25 °C (77 °F), up to 90%
relative humidity non-condensing at 42 °C
(108 °F)
Vibration
Operating conditions
20 Hz to 2,000 Hz, 14.6g
Mechanical
Shock
Non-operating conditions
±40g; Half sine, 11 msec
Operating conditions
±20g; Half sine, 11 msec