Connecting main power, Auxiliary supply (for drive logic), Auxiliary supply – ElmoMC ExtrIQ Digital Servo Drives-Hawk User Manual

Page 27

Advertising
background image

Hawk Installation Guide

Installation

MAN-HAWIG (Ver. 1.401)

www.elmomc.com

27

3.7.2.

Connecting Main Power

Connect the VP+, PR and PE pins on the Hawk in the manner described in Section 3.5
(Integrating the Hawk on a PCB).

Note:

The source of the 12 to 195 VDC Main Power Supply must be isolated.

Figure 6: Main Power Supply Connection Diagram (no Auxiliary Supply)

3.8. Auxiliary Supply

(for drive logic)

Notes for 12 to 195 VDC auxiliary supply connections:

The source of the 12 to 195 VDC Auxiliary Supply must be isolated.

Connect the VL and PR pins on the Hawk in the manner described in Section 3.5 (Integrating
the Hawk on a PCB).

Pin

Function

Pin Positions

VL

Auxiliary Supply Input

PR

Supply Input Return

Caution:
Power from the Hawk to the motor
must come from the Main Supply
and NOT from the Auxiliary Supply.

Table 2: Auxiliary Supply Pins