• Do not allow the plunger to rotate during

adaptor installation. Plunger rotation may
damage the internal seals and/or the plunger
return spring (if equipped).

• Use care when installing adaptors and

attachments. Be careful not to nick or mar the
plunger rod surface.

• Collar threads are rated for the full capacity of

the cylinder when fully engaged in attachments.

WARNING: Some cylinder attachments
require that the cylinder be used at no
more than 50% of its rated capacity. Refer
to the accessory instruction sheet for
additional information.

4.0 OPERATION

Operate the hydraulic pump to advance and retract
the cylinder. Some single-acting cylinders are spring-
return, others are load-return. The speed of retraction
is aff ected by the length of the hose and other
restrictions in the line. Double-acting cylinders are
powered in both directions by the pump.

The cylinder stop ring is designed to take the full load.
However, to reduce cylinder wear, use less than full
stroke and pressure when possible.

5.0 RELIEVING TRAPPED PRESSURE

Pressure can sometimes become trapped in a
hydraulic cylinder if a hose is disconnected before
pressure is completely relieved.

If a trapped pressure condition occurs, always use the
Enerpac model CT-604 coupler bleed tool (available
from your Authorized Enerpac Distributor) to safely
relieve the remaining pressure.

DANGER: Never attempt to relieve hydraulic
pressure by loosening a coupler. Trapped
hydraulic pressure can cause a loosened

coupler to dislodge unexpectedly with great force.
Serious personal injury or death will result if the
coupler becomes a projectile and strikes persons
working in the area.

WARNING: Loosening a coupler may
result in an escape of high pressure oil
that can penetrate the skin. Serious
personal injury or death could result.

WARNING: Never use a hammer and
punch (or other similar method) to unseat
a coupler check ball that is under
pressure. Serious personal injury or death

could result due to the sudden and uncontrolled
escape of high pressure oil.

6.0 MAINTENANCE

1. Use only Enerpac oil with the cylinder. The use of

any other oil may invalidate your warranty.

2. Use dust cap(s) when cylinder is disconnected

from the hose(s). Keep the entire cylinder clean to
prolong its life.

3. Single-acting cylinders only: Before long term

storage, fully extend and retract the plunger once.
Then, store the cylinder upside-down. This will
help protect the cylinder from corrosion.

7.0 TROUBLESHOOTING

Refer to the troubleshooting chart for a list of
typical cylinder problems and possible causes. The
troubleshooting chart is not all-inclusive, and should
be considered only as an aid to help diagnose the
most common problems.

The cylinder should be repaired only by trained and
experienced hydraulic technicians.

WARNING: Single-acting cylinders are
spring-loaded and require special
disassembly techniques to prevent
personal injury.