Installing the hpl lamp, English ce source fourpar • 7 – ETC Source Four CE PAR EA and MCM User Manual

Page 9

Advertising
background image

English

CE Source FourPAR • 7

Installing the HPL lamp

Always replace the lamp if it becomes damaged or deformed.

1.

Disconnect the unit from power before installing the lamp.

2.

Loosen the knurled bolt on the back of the lamp housing and pull
the housing straight out from the back of the luminaire.

3.

Remove the HPL lamp from its box, holding it by the base.

Note:

To avoid premature lamp failure, do not touch the lamp glass
with your fingers. If you touch the lamp during installation,
clean it carefully with rubbing alcohol and a clean, lint-free
cloth before operation.

4.

Line up the flat sides of the lamp base with the brackets on either
side of the socket (

Figure 1

).

5.

Push down on the lamp base until the lamp is firmly seated. Make
sure that the lamp is fully seated, with the bottom of the lamp heat
sink flush to the lamp housing casting.

Caution!

Improperly installed lamps cause premature lamp
failure and socket problems.

6.

To reinstall the lamp housing, center it on the reflector and the bolt
hole, then tighten the knurled bolt to secure the lamp housing in
place.

Lamp code

Watts Volts

Color temp Ave rated life

HPL 575/230

575

230

3,200ºK

400 hour

HPL 575/240

575

240

3,200ºK

400 hour

HPL 375/115

375

115

3,250ºK

300 hour

HPL 375/115X

375

115

3,050ºK

1,000 hour

HPL 550/77

550

77

3,250ºK

300 hour

HPL 550/77X

550

77

3,050ºK

2,000 hour

HPL 575/115

575

115

3,250ºK

300 hour

HPL 575/115X

575

115

3,050ºK

2,000 hour

HPL 575/120

575

120

3,250ºK

300 hour

WARNING!

Let lamp cool before changing.

Euro.

American

Figure 1

HPL lamp

Lamp brackets

Knurled bolt

Lamp housing

CES4PAR(4Lang)Eng.fm Page 7 Tuesday, August 31, 1999 2:35 PM