Operating Instructions Read Heads/Actuators CEM-A-...

EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49/711/75 97-0 Fax +49/711/75 33 16 www.euchner.de [email protected]

Subject to technical modifications; no r

esponsibility is accepted for the accuracy of this information. © EUCHNER GmbH + Co. KG 114342-04-05/13 (translation of the original operating instructions)

Setup and functional check

Pay attention to the information in the system manual

for the evaluation unit used during setup.

Danger of fatal injuries as a result of faults in

installation and functional check.

f

Before carrying out the functional check,

make sure that there are no persons in the

danger area.

f

Observe the valid accident prevention regula-

tions.

After installation and any fault, the safety function

must be fully checked. Proceed as follows:

f

Switch on operating voltage.

The machine must not start automatically.

f

Close all safety guards.

f

Activate the guard locking.

f

Test the locking force by trying to open the safety

guard. The adhesive force of 500 N or 1,000 N is

attained when U

CM

is applied.

Technical data

Read head

Parameter

Value

Material

- Housing

- Read head CES

- Solenoid

Aluminum

Plastic (PPS)

Galvanized steel

Weight

- CEM-A-LE05...

- CEM-A-LH10...

Approx. 0. kg

Approx. 0.9 kg

Installation position

Any

Degree of protection

according to IEC 60529

IP67

Ambient temperature

-25 ... +50 °C

Operating distance with center

offset m=0

- Assured switch-off distance S

ar

- Switch-on distance typ.

- Switching hysteresis

20 mm

2 mm

0.7 mm

Connection to evaluation unit

(Plug connector X3)

Plug connector M8 (male

socket, 3-pin), suitable for snap-

action and screw terminals

Max. cable length

25 m

External LED connection

(plug connector X2, only

CEM-A-LH10...)

Plug connector M8 (female

socket, 4-pin), suitable for

screw terminals

Max. current consumption of

external LED

500 mA

Solenoid
Locking force (not monitored)

- CEM-A-LE05...

- CEM-A-LH10...

500 N

1,000 N

Adhesive force due to remanence

- CEM-A-LE05K-S2(-EX)

- CEM-A-LE05R-S2

- CEM-A-LH10K-S2

- CEM-A-LH10R-S2

approx. 10 N ± 25 %

approx. 0.5 N

approx. 40 N ± 25 %

approx. 0.7 N

Max. permissible center offset be-

tween solenoid and mating plate

± 2.5 mm

Operating voltage U

B

(plug connector X1)

DC 24 V +10%, -15%

reverse polarity protected

Control voltage U

CM

(plug con-

nector X1)

DC 24 V +10%, -15%, reverse

polarity protected with free-

wheeling diode

Current consumption

Read heads with remanence

- at connection X1.1 (U

CM

)

- CEM-A-LE05K-S2(-EX)

- CEM-A-LH10K-S2

100 mA

225 mA (without external LED)

Current consumption

Read heads without remanence

- at connection X1.1 (U

CM

)

- CEM-A-LE05R-S2(-EX)

- CEM-A-LH10R-S3

- at connection X1.2 (U

B

)

- CEM-A-LE05R-S2(-EX)

- CEM-A-LH10R-S3

15 mA

15 mA (without external LED)

at UCM = 0 V

12 mA

at UCM = 24 V 100 mA

at UCM = 0 V

12 mA

at UCM = 24 V 225 mA

Duty cycle

100 %

Power consumption

- CEM-A-LE05K-S2(-EX)

- CEM-A-LE05R-S2

- CEM-A-LH10K-S3

- CEM-A-LH10R-S3

approx. 2.5 W

approx. 2.8 W

approx. 5.4 W

approx. 5.8 W

Operating voltage connection

(plug connector X1)

Plug connector M8 (male

socket, 4-pin)

For CEM-A-LE05... LED, yellow,

integrated into the plug (see

circuit diagram)

Actuator

Parameter

Value

Material

- Housing

- Read head CES

- Solenoid

Aluminum

Plastic (PPS)

Galvanized steel

Weight

- CEM-A-BE05...

- CEM-A-BH10...

Approx. 0.18 kg

Approx. 0.30 kg

Installation position

Active face opposite CES

read head

Degree of protection

according to IEC 60529

IP67

Ambient temperature

-25 ... +50 °C

Adjustment angle (around point X,

see dimension drawing)

± 4 °

-4

-2

-3

-1

1

3

2

4

0

1

2

3

4

Center offset m [mm]

Distance s [mm]

OFF

ON

Hysteresis

Switch-on

distance

ON

OFF

Hysteresis

Distance s

S

a0

Output state

Switch-off

distance

OFF

Actuator

Read head

s

m

ON

Observe safe switch-off

distance s

ar

= 20 mm on

internal component failure.

Safety outputs are safely

switched off.

Typical operating distance

With evaluation unit CES-A-...B and CES-AZ-...B

Figure 2: Typical operating distance

Service and inspection

No servicing is required, but regular inspection of the

following is necessary to ensure trouble-free long-term

operation:

f

correct switching function

f

secure mounting of components

f

dirt and wear

f

loose cable connections or plug connectors.

If damage or wear is found, the complete

read head and actuator assembly must be

replaced.

Replacement of individual parts or assemblies

is not permitted!

Exclusion of liability under the following

circumstances

f

incorrect use

f

non-compliance with safety regulations

f

installation and electrical connection not per-

formed by authorized personnel.

f

failure to perform functional checks.