Euchner safety parts, Safety system and enabling switches, 1 euchner safety parts – EUCHNER AS User Manual
Page 3

Safety Monitors - AS-i Quick Reference - 08/2014
3
1 EUCHNER Safety Parts
1.1 Parameters for all EUCHNER electromechanical safety
switches, non-contact safety system and enabling switches
Parameters for all electromechanical safety switches with and without locking and
non-contact safety switches CESx1 (094230 + 096631)
Safe slaves are built according to Specification 2.11 for standard slaves
All parameters of safety switches are pre-programmed at delivery and can be read with a
programming device.
The following values are adjusted:
Parameters for enabling switches and non-contacts safety switches CESx4 (097660 +
100206)
Safe slaves are built according to Specification 2.11 for standard slaves
All parameters of safety switches and enabling switches are pre-programmed at delivery and
can be read with a programming device.
The following values are adjusted:
IO Code:
7
ID Code:
B
ID 1:
F
ID 2:
E
IO Code:
0
ID Code:
B
ID 1:
F
ID 2:
E