State of as-i safety switches, 2 state of as-i safety switches – EUCHNER AS User Manual
Page 32

Safety Monitors - AS-i Quick Reference - 08/2014
32
4.2 State of AS-i Safety Switches
GP, NZ, NX, SGP
Programming: dual channel dependent
State
Monitor diagnostics
Door closed
green
With local acknowledgment: yellow blinking at
startup
Intermittent state at closing or opening of
door: channel 1 (internally) open
At opening: yellow blinking
At closing: red
After rundown of synchronization time: yellow
blinking
Intermittent state at closing or opening of
door: channel 2 (internally) open
Door open
red
Address 0 or no communication
grey
TP..AS2
Programming: dual channel dependent
State
Monitor diagnostics
Door closed, lock open or closed
green
Intermittent state at closing or opening of
door: channel 1 (internally) open
At opening: yellow blinking
At closing: red
After rundown of synchronization time: yellow
blinking
Intermittent state at closing or opening of
door: channel 2 (internally) open
Door open
red
Address 0 or no communication
grey