IMPORTANT

TURN OFF THE POWER AT THE MAIN FUSE OR

CIRCUIT BREAKER BOX

BEFORE STARTING INSTALLATION

Carefully unpack and identify all parts before

assembly. Bulb

not included.

1. Attach mounting bar securely to ceiling junction box with

two machine screws (supplied with junction box) through

slot at each end of mounting bar. Note: mounting bar should

be installed with "GND" imprint and/or two dimples facing

down.

2. Fasten one hex nut about 3/4" (19 mm) down from one end

of threaded pipe. Then screw same end of threaded pipe into

center hole in mounting bar. At this point test install the main

frame onto ceiling through this threaded pipe and make

certain 3/8" (10 mm) of pipe protrude below. If not, then

adjust the threaded pipe location by screwing up or down

accordingly. Once correct threaded pipe location has been

adjusted, remove main frame and tighten hex nut against

mounting bar. Make certain not to spin threaded pipe during

tightening.

3. Spread the electrical wires so that the black wires are on one

side of the outlet box and the white wires are on the other

side.

4. Electrical connections:

Connect the white wire from the fixture to the white wire of

the outlet box.

Connect the black wire from the fixture to the black wire of

the outlet box.

NOTE: Black outlet box wire may be red, round & smooth

and/or have copper conductor. White outlet box wire may be

square & ridged and/or have a silver conductor.

5. Grounding Connection:

Connect fixture ground wire (without insulation) to ground

wire from outlet box (usually with green insulation) with

wire connector (not provided).

IMPORTANT: Never connect ground wire to black or white

power supply wires.

6. While making certain all electrical wires are tucked inside of

main frame, install the main frame by fastening with a lock

washer and coupler onto the top threaded pipe.

7. Install a hex nut onto one end of center pipe leaving about

3/8" (10mm) thread exposed. Screw same end of pipe into

coupler. Tighten hex nut.

8. Install bulb (not included). See relamping label located at

socket area for type and maximum allowed wattage.

9. Install shade by slipping through the installed center pipe and

then fastening with finial. IMPORTANT: Do not over tighten.

Assembly Instructions For

FM313

Mounting Bar

Outlet Box

Mounting Screw

Socket

Bulb

(not included)

Outlet Box

Supply Ground Wire

Supply Wire

Fixture Wire

Fixture Ground Wire

Shade

Main Frame

Lock Washer

Coupler

Finial

(E) 12/08

Center Pipe

Advertising