IMPORTANT

TURN OFF THE POWER AT THE MAIN FUSE OR CIRCUIT

BREAKER BOX BEFORE STARTING INSTALLATION

Carefully unpack and identify all parts before

assembly. Bulb not

included.

1. Install glass panels: (see fig. 1)

A. Gently grabbing onto a glass panel, slip inside of main frame.

Make certain top edge of panel check onto upper tabs located at

inside of main frame

B. Secure glass panel by bending tabs located at bottom.

C. Repeat rest panels.

2. Gently pull supply wires out from ceiling outlet box.

3. Attach mounting strap securely to ceiling outlet box with two

machine screws (supplied with outlet box) through slot at each end

of mounting strap. Note: mounting strap should be installed with

"GND" imprint and/or two dimples facing down.

4. Fasten one hex nut about 3/4" (19 mm) down from one end of

threaded pipe. Then screw same end of threaded pipe into center

hole in mounting strap. At this point test install the main frame onto

ceiling through this threaded pipe and make certain 3/8" (10 mm) of

pipe protrude below. If not, then adjust the threaded pipe location by

screwing up or down accordingly. Once correct threaded pipe

location has been adjusted, remove main frame and tighten hex nut

against mounting strap. Make certain not to spin threaded pipe

during tightening.

5. Spread the electrical wires so that the black wires are on one side of

the outlet box and the white wires are on the other side.

6. Electrical connections:

Connect the white wire from the fixture to the white wire of the

outlet box.

Connect the black wire from the fixture to the black wire of the

outlet box.

NOTE: Black outlet box wire may be red, round & smooth and/or

have copper conductor. White outlet box wire may be square &

ridged and/or have a silver conductor.

7. Grounding Connection:

Connect fixture ground wire (without insulation) to ground wire

from outlet box (usually with green insulation) with wire connector

(not provided).

Note: If there is no supply ground wire at outlet box then attach

fixture ground wire securely onto green grounding screw located at

mounting strap.

IMPORTANT: Never connect ground wire to black or white supply

wires (from outlet box).

8. Place main frame through top threaded pipe so that it sits flush

against ceiling. Be sure all wires are tucked inside. Secure main frame

to ceiling by fastening lock washer and coupler onto top threaded

pipe.

Note: Coupler must turn at least 3 times, if it does not you must

remove coupler and lengthen threaded pipe accordingly.

9. Install long threaded pipe by screwing into bottom of coupler. Note

correct position of center pipe at illustration.

10. Install bulb (not included). See relamping label located at socket area

for type and maximum allowed wattage.

11. Slip glass plate through long threaded pipe until it checks inside of

main frame. Lock glass plate by fastening finial. IMPORTANT: Do not

over tighten.

Assembly Instructions For