Feiss OL5413 User Manual

Assembly instructions for ol5413, E) 4/07

Advertising
background image

(E) 4/07

ASSEMBLY INSTRUCTIONS FOR OL5413

Bulb

(not included)

Glass Plate

IMPORTANT

TURN OFF THE POWER AT THE MAIN FUSE

OR CIRCUIT BREAKER BOX

BEFORE STARTING INSTALLATION

Lock Washer

Rubber Washer

Coupler

Finial

Carefully unpack and identify all parts before

assembly. Bulb is not included.

1. If you are replacing an existing fixture, disconnect 

and remove the old fixture. Expose the supply 

wiring from the outlet box.

2. Screw the small threaded pipe 3 complete turns into

the flat side of mounting strap and lock in place

with hex nut.

3. Fasten the mounting strap to the outlet box using 

the two screws supplied with the outlet box.

4. Spread the electrical wires so that the black wires 

are on one side of the outlet box and the white wires

are on the other side.

5. Grounding Connection: 

     This fixture is provided with a ground wire. 

Connect fixture ground wire to ground wire from

outlet box with wire connector (not provided).

 

     Never connect ground wire to black or white supply

wires.

6. To make electrical connections:

  Connect the white wire(s) from the fixture to the 

white wire of the outlet box. Connect the black 

wire(s) from the fixture to the black wire of the 

outlet box. NOTE: Black outlet box wire may be 

red, round & smooth and/or have copper conductor. 

White outlet box wire may be square & ridged and/

or have a silver conductor.

7. Place fixture through short threaded pipe so that

fixture sits flush against ceiling. Be sure all wires

are inside fixture. Secure fixture to ceiling by

screwing coupler onto small threaded pipe. Coupler

must turn at least 3 times, if it does not you must

lengthen threaded pipe accordingly.

8.  Install bulbs (not included). See relamping label

located at socket area for type and maximum

allowed wattage.

9.  Install a hex nut onto one end of threaded pipe

leaving about 1/2" (13mm) thread exposed. Screw 

same end of threaded pipe into coupler. Tighten hex

nut.

10. Carefully slip glass plate through same pipe until it

tucks into bottom of fixture. Then slip rubber

washer and secure all together by fastening with

finial. IMPORTANT: Do not over tighten finial.

Supply

Ground Wire

Mounting Strap

Short Threaded Pipe

Long Threaded Pipe

Outlet Box

Mounting Screws

(not supplied)

Fixture

Ground Wire

Fixture

Wire

Fixture

Supply Wire

Outlet Box

Ceiling

Advertising