Mechanical installation – Festo HSW-...-AP/AS User Manual
Page 40

HSW−...−AP/A S
Festo HSW−...−AP/AS 0812b English
40
Mechanical installation
The HSW is supplied ready for fitting.
S
If necessary, remove the protective cover before fitting.
S
Make sure that after fastening there is sufficient space for fitting the
components.
S
First fit the add−on components, and for HSW−...−AS the external drive.
S
Make sure that the fastening surface can support the weight of the HSW
S
Fit the HSW only onto a flat fixed surface.
S
Select one of the following fastening methods:
ć Direct fastening via the through holes
and centring sleeves in the sub−base.
[mm]
HSW−
10−...
HSW−
12−...
HSW−
16−...
H1 = L1
20
20
20
H2 = L2
56.5
80
100
H3 = L3
49
12.5
12
H4 = L4
20
20
20
H5 = L5
31
37.5
50
Ø D
5.5
5.5
5.5
Number
of screws
Min. 2
Min. 4
Min. 4
Fig. 7
ć Fastening to the rear of the sub−base
with slot nuts HMBN−8 to profile
columns HMBS (example: Fig. 8).
Fig. 6
Fig. 8