Pneumatic installation – Festo HSW-...-AP/AS User Manual

Page 45

Advertising
background image

HSW−...−AP/A S

Festo HSW−...−AP/AS 0812b English

45

S

Carry out a manual check of the following after each adjustment
(without pressurizing the drive)ā:

ć Has the desired end position been reached?
ć Are the link parts aligned without offset?

S

In order to do this, swing the moveable
mass into the end positions.

ć by hand or
ć on the drive using the hex socket

(square in HSW−10; see Fig. 17).

S

When doing this, check that the double
rollers run smoothly in the path guide.

S

If necessary, correct the alignment of the link parts.

S

Fasten the protective cover of the handling module.

Pneumatic installation

Connecting the drive for HSW−...−AP:

S

Use one−way flow control valves of GRLA
for setting the swivel speed.

The speed will be reduced by the
throttling of the exhaust air.

S

Screw in both one−way flow control
valves on the drive.

S

Connect the tubing of the drive.

Connecting the add−on components:

S

Make sure that the moving pneumatic
tubing and electric cables are laid corĆ
rectly (example Fig. 19). Installation kit
MKRP (see chapter Accessories") enĆ
ables the tubing and cables to be grouped
together in a flexible installation tube.

Fig. 17

Fig. 18

Fig. 19

Advertising