Flint & Walling 230V Pond and Fountain Systems FPS10021 User Manual

Page 2

Advertising
background image

2

95 North Oak St. • Kendallville, IN 46755 • 800-742-5044 • © 2012 All rights reserved.

Floating Pond Pump System 1/2, 3/4 & 1 HP

230V Models FPS05021, FPS07021, FPS10021

Operating Instructions & Parts Manual

Description

This pump system is designed for decorative use and can improve water aeration.
Operates in 5 feet of water or deeper. Do not pump water above 120˚ F. Make
your floating fountain system even more dramatic at night by adding NightBright
lighting system 023069. See specifications for water displacement and fountain
height.

General Safety Information

Carefully read and follow all

safety instructions in this manual

and on pump. Keep safety labels in
good condition. Replace missing or
damaged safety labels.

This is a SAFETY ALERT SYMBOL.
When you see this symbol on

the pump or in the manual, look for
one of the following signal words and
be alert to the potential for personal
injury or property damage.

Warns of hazards
that WILL cause

serious personal injury, death or major
property damage if ignored.

!

Warns of hazards
that CAN cause

serious personal injury or death, if
ignored.

Warns of hazards
that MAY cause

minor personal injury, product or
property damage if ignored.

IMPORTANT: Indicates factors
concerned with operation, installation,
assembly or maintenance which could
result in damage to the machine or
equipment if ignored.
NOTE: Indicates special instructions
which are important but are not
related to hazards.

!

Read these
warnings and

instructions carefully. Failure to follow
could result in serious bodily injury
and/or property damage.

!

This unit
not

tested for use in swimming
pool areas.

Electrical installations shall be
in accordance with National

Electric Code (NEC) and all applicable

local codes and ordinances. A licensed
electrician should perform installation.

Be sure
system is

connected to a
circuit equipped
with a fuse or
circuit breaker of
proper size.

Protect the
power cable

from coming
in contact with
sharp objects,
oil, grease, hot

surfaces or chemicals. DO NOT kink
the power cable. If damaged replace
immediately.

Install all electrical equipment
in protected area to prevent

mechanical damage which could produce
serious electrical shock and/or equipment
failure.

NEVER leave the control box,
fused disconnect switch,

or covers open (either partially or
completely) when not being worked
on by a competent electrician or
repairman.

Always disconnect power source
before performing any work

on or near the motor or its connected
load. If the power disconnect point
is out-of-sight, lock it in the open
position and/or tag it to prevent
unexpected application of power.
Failure to do so could result in fatal
electrical shock or bodily injury.


DO NOT use this system to
pump flammable liquids such

as gasoline, fuel oil, kerosene, etc.
Failure to follow the above warning

could result in property damage and/or
personal injury.

Unpacking

Unpack and inspect system for damage.
Verify you have received the following
components:
1. Instructions
2. Warranty
3. Pump/float unit.

a. Float with nozzle (Water Lilly 2A)

attached by 4 screws.

b. Screen attached to float by 2

hex bolts with lock washers and
2 eyebolts with hex nuts 180°
apart.

c. 100ft cord secured to bottom cap

with strain relief.

4. Control center.

a. Pump timer
b. Light timer
c. 4 mounting brackets with bolt kit

5. Shrink tube splice kit
6. 2 additional nozzles

a. Sky Cannon (Fig 2)
b. Water Trumpet (Fig 3)

Specifications

230V, 1/2, 3/4 or 1 HP
Requires 5' or greater water depth
100' power cord
Water Lily attachment nozzle displaces:
1/2 HP 4,900 GPH at 15 Ft.
3/4 HP 5,825 GPH at 22 Ft.
1 HP 6,150 GPH at 24 Ft.
Sky Canon attachment nozzle displaces:
1/2 HP 3,300 GPH at 15 Ft.
3/4 HP 4,100 GPH at 35 Ft.
1 HP 4,200 GPH at 41 Ft.
Water Trumpet attachment nozzle
displaces:

1/2 HP 2,700 GPH at 13 Ft.
3/4 HP 3,400 GPH at 20 Ft.
1 HP 3,600 GPH at 22 Ft.

Hazardous voltage.

Can shock, burn

or cause death.
Ground system before
connecting to power
supply.

Advertising