c. Place power cord so that it rests

on bottom of pond away from
sharp rocks or vegetation so it
can be easily removed without
being damaged or becoming
entangled. Leave enough slack to
accommodate anticipated water
level fluctuations.

NOTE: It is suggested that the
underwater power cables be installed
in conduit from the panel to 4 -5 ft into
the water to prevent possible cable
damage.
4. Before connecting the unit to the

control center, check to insure there
is no leakage to ground. This can be
done by using an ohm meter and
setting the scale to its highest setting
(i.e. Rx100K). Connect one ohmmeter
lead to the unit power cord ground
and to one of the power conductors.
It should read infinite or at least 2
mega ohms. Repeat with the other
conductor. If reading is below 2
mega ohms on either conductor
contact Customer Service Help Line
at 1-800-742-5044.


"NO SWIMMING” AND OR
WARNING SIGNS SHOULD BE

POSTED PER STATE AND LOCAL CODES.

Water leaving
nozzle is at high

velocity and can cause bodily injury if
contact is made.


Always use caution when
operating electrical controls

in damp areas. If possible, avoid all
contact with electrical equipment
during thunderstorms or extreme
damp conditions.

System Control Center

installation and electrical

connection

1. All work must be done in compliance

with local and national electrical
codes by licensed, qualified
electrician. Refer to Fig. 6 in these
instructions or on inside of panel
door for proper wiring.

2. Control Center mounting location.

(See fig. 4 for typical installation)
a. Mount control center a minimum

of 3 feet above ground and a
minimum of 3 feet above the high
water level in a flood zone.

b. Mount control center a minimum

of 5 feet horizontally from
shoreline during maximum flood
condition. (Control center must not
be accessible from water)

c. Always keep control center door

closed, bolted and locked when not
servicing.

3. Have a licensed, qualified electrician

make final connections of fountain
and optional lights to system control
center.

4. Have a licensed, qualified electrician

install disconnecting means in
compliance with local and national
electrical codes.

5. Have a licensed, qualified electrician

make connection to power source.

6. Apply power to unit and set timers

as described in the Setting Timers
section.

7. Test the ground fault interrupter

for proper operation by depressing
the “test” button. (See Fig. 6) The
fountain should shut off. Press the
“reset” button to restart the system.
If pressing the “test” button does not
stop the unit, immediately shut off
power to unit and contact Customer
Service Help Line at
1-800-742-5044.

!


FAILURE TO CONNECT THIS UNIT

TO A PROPERLY GROUNDED POWER
SUPPLY MAY RESULT IN SEVERE
ELECTRICAL SHOCK.

Setting timers

NOTE: Set the pump timer for all
installations. Set the light timer when
installing the optional NightBright
lighting system.
IMPORTANT
: Rotate dial in clockwise
direction only! Rotating dial counter
clockwise will damage timer!
1. Set the on-off time zones.

a) 6 trippers (3 red-on and 3 white-

off) stored below the dial, are
included with each timer for
setting up to 3 on-off time zones.

b) Install the red tripper at the desired

on time and the white tripper at
the desired off time.

c) Rotate the dial clockwise to verify

operation of the trippers.

d) The timer may be overridden by

turning the small on/off dial in the
upper right hand corner of the
timer. Timer will automatically reset
when next time zone occurs unless
manual override was set within 1
hour of on or off cycle.

2. Setting the clock. (24 hr clock)

a) Turn the dial clockwise until the

arrowhead is aligned with the
proper time.

b) The timers include built in battery

backup for maintaining time
during power outages.