Appliances Equipped with Castors:

Prior to installation, the four castors, supplied loose with the

grill, must be securely located on the underside of the base.

The castors fitted with a brake must be located at the front of

the grill.

• Once castors are installed, adjust the unit by turning

them clockwise to raise the unit and counterclockwise to

lower the unit.

• Adjust the castors until the grill plate is level and at the

proper height.

• Screw the lock nut on each castor tight against the

bottom of the unit.

• When the unit is in place, lock the front castors to prevent

movement.

Grill plate must be level front to back, side to side and

diagonally. This leveling must be done with the unit under

the hood and in it’s normal operational position to prevent

warping of the grill plate.

Electrical Connections:

Electrical connections must be in accordance with the

current IEE Wiring Regulations. The supply should have a

contact separation of at least 3mm on all poles. Adequate

means of disconnection of the supply must be provided.

It is recommended that this grill be connected to a residual

current (earth leakage) device with a tripping current not

exceeding 30mA. The leakage current of this grill will not

exceed 5mA.

CAUTION: Prior to installation, check the electrical supply

to ensure input voltage and phase match the equipment

voltage rating and phase. See data plate located rear left side

of grill and lower front panel.

The entry point for the electrical connection is located on

the base of the appliance. Remove the punch-out plate, and

punch out the required size to the supply cable. Secure the

cable in place with a gland fitting and suitable means of

strain relief.

All electrically operated appliances must be electrically

earthed in accordance with local codes; or in the absence

of local codes, with the latest edition of National Wiring

Regulations. A wiring diagram is located on the rear panel of

the grill. See rating plate in rear of grill, or lower front panel

for proper voltages.

Burner Manifold Pressure Test/Adjustment:

Burner operating gas pressure can be checked at the outlet

side of the gas valve at the pressure test point.

To adjust the burner pressure:

1. The pressure test nipple is located in the gas valve on the

side opposite the burner.

2. Remove the sealing screw from the pressure test nipple

and connect a manometer.

3. Remove the sealing cap on the gas valve regulator, turn

on the grill, and adjust the screw in the regulator to give

the correct pressure.

4. Turn off the grill, refit the regulator sealing cap, remove

the manometer, replace the seal screw in the test nipple

and test for gas leaks.

Gas pressures should be checked by the local Gas Company

or an authorized service agency only.

Test all piping and connections for gas leaks. A rich soap

solution should be used for this purpose. Never use a flame.

Burner Ignition Verification by the Installer:

Once the grill is properly installed, turn the grill power switch

on. Press the ON/OFF switch on the grill control to heat the

grill in Standby Mode. The will attempt to ignite the burners.

Verify Burner Ignition as Follows:

1. The controls will attempt to ignite the burners when the

grill calls for heat to the griddle plate.

2. If ignition does not occur on the first attempt, the lower

LED (for the grill plate) will begin to flash to alert the

installer that the first attempt at burner ignition has

failed.

3. The control will then attempt to ignite the burners up to

four (4) more times.

4. If, after four (4) attempts, the burners have not ignited,

the control will shut down and display “IGNITION ERROR.”

5. Inspect the gas and ignition systems for possible