Dimensions and specifications continued – Garland GF SENTRY SERIES INFRA-RED SALAMANDER BROILERS User Manual

Page 6

Advertising
background image

Part # 4526026 Rev. 03 (06/12/14)

Page 6

DIMENSIONS AND SPECIFICATIONS continued

CE Gas Categories

Country

Gas

Category

Gas Type

Pressure

(mbar)

GB, IE, ES, PT, GR

I

2H

G20

20

GB, IE, ES, PT, BE, FR

I

3P

G31

37

FR, NL, DE, ES

I

3P

G31

50

Gas Pressure And Ratings

CE & General International Countries

Pressure Setting / Injector Size

MODELS

2nd Family, Group H

G20 @ 20 mbar inlet

3rd Family, Group P

G31 @ 37/50 mbar inlet

Setting

Pressure*

Injector Size

Setting

Pressure*

Injector Size

mbar

DMS

mm

mbar

DMS

mm

GFIR

20

1.6mm

1.6

37

1.1mm

1.1

50

61

0.99

* No appliance pressure regulator used, pressure measured at the test nipple on main manifold with all burners lit.

Heat Input (Gross)

MODELS

2nd Family, Group H

(G20 @ 20 mbar) NAT

3rd Family, Group P

(G31 @ 37/50 mbar) PROPANE

# Of

Burners

kW Per Burner

kW Per Burner

GFIR

4.2

4.2

2

Setting Pressure For “MIN” Tap Position

MODELS

2ND Family, Group H

(G20 @ 20 mbar) NAT. GAS

3RD Family, Group 3P

(G31 @ 37/50 mbar) PROPANE

mbar

“ W.C.

mbar

“ W.C.

GFIR

10.5

4.2

23

9.4

North America

Operating Manifold Pressure

Natural 4.0” wc

Propane 10.0” wc

Total Input

BTU/H

BTU/H

28,000

26,000

Gas input ratings shown here are for installations up to 2,000 ft. (610m) above seal level. Specify altitudes over 2,000 ft.

Gas Inlet Size

Connection

(North America &

Australia)

Connection CE Models

(ISO7-1)

3/4” NPT Top Gas

Connection

3/4” (19.1mm) BSPT

Australian Market

Operating Manifold Pressure

Natural 1 kPa (4.0” wc)

LPG 2.49 kPa (10.0” wc)

Total Input

MJ/H

Injector Dia.

MJ/H

Injector Dia.

21.0

2.4 mm

21.0

1.4mm

Advertising