Appendix 3 – General Machine Products 89910 Whisper Micro Fiber Cable Blowing Machine User Manual

Page 28

Advertising
background image

Page 28

General Machine Products Co., Inc.

• Press and hold both and buttons.
o After 5 seconds ‘ProG’ will be displayed. Releasing the buttons will display ‘no’
• Press
o ‘Yes’ is displayed
• Hold and press
o ‘InPol’ is displayed
• Press until ‘nPn’ is displayed
• Hold and press
o ‘Filter’ is displayed
• Press until ‘oFF’ is displayed
• Hold and press
o ‘InPut’ is displayed
• Press until ‘Cnt.dir’ is displayed
• Hold and press
o ‘FAc.Cnt’ is displayed
• Press
• Enter value 00.0006 for metres, 00.0019 for feet
o Use to move to next digit
o Use to increment digit (this instruction applies to all following number inputs)
Hold and press
o ‘diV.Cnt’ is displayed
• Press
• Enter value 01.0000
• Hold and press
o ‘dP.Cnt’ is displayed
• Press until ‘0’ is displayed
• Hold and press
o ‘rES.Cnt’ is displayed
• Press until ‘MAnrE’ is displayedat
• Hold and press
o ‘FAc.tAc’ is displayed
• Press
• Enter value 00.0006 for metres, 00.0019 for feet
• Hold and press
o ‘diV.tAc’ is displayed
• Press
• Enter value 01.0000
• Hold and press
o ‘dP.tAc’ is displayed
• Press until ‘0’ is displayed
• Hold and press
o ‘disPm’ is displayed
• Press until ‘Min-1’ is displayed
• Hold and press
o ‘Wait0’ is displayed