General Machine Products Co., Inc.

2. Critical points that dramatically affect the operation of the cable blowing
machine.

Pressure on the cable should be set as per the instructions.

Rollers to be closed at all times when cable is installed into machine.

Cord seals in air chamber correctly fitted to provide good sealing.

Correct cable seal fitted.

Tube fully connected and pressure-tested.

Tube connecting fittings are suitable for operating at 220 PSI air pressure.

Tube clamp securely tightened.

Compressor capacity 220 PSI and suitable for size of tube being used.

Cable drum must be located directly behind and in line with the blowing machine.

Air chamber, drive rollers, cable guides, must be clean and free from debris, sludge, dirt,
water and lubricant.

The cable must be hand guided into the blowing machine through a dry clean cloth by the
operator wearing work gloves.

Ensure the compressed air supply is not applied to the cable until required amount of ca-
ble has been installed.

The counter/display is powered by (2) 9 volt batteries. To maximize battery life, turn dis-
play off by pressing power button on left side of display box when unit is not in use.