5.0 OPERATING PROCEDURE

IT IS IMPERATIVE THAT ALL PERSONS USING, OPERATING OR MAINTAINING THIS CABLE
BLOWING MACHINE:

▪ HAVE RECEIVED COMPREHENSIVE TRAINING IN THE USE OF THIS MACHINE.

▪ ARE COMPETENT TO USE IT,

▪ AUTHORIZED TO USE IT AND

▪ HAVE READ AND UNDERSTOOD THIS MANUAL

▪ GENERAL MACHINE PRODUCTS CO., INC. CANNOT BE HELD RESPONSIBLE FOR

MISUSE OF THIS EQUIPMENT.


Set up for installing cable with the machine mounted above ground:


Position the machine in line with the route of the duct.
Position the cable drum behind the machine and in line with the machine. See sketch below (this shows a plan
view of the recommended set up).





Ensure the machine is secure (either on its own stand or a separate suitable stand).
Ensure the machine is fitted with the appropriate guides and collets to suit the cable being installed and tubes
into which the cable is to be installed. (See Appendix 1 for details of interchangeable parts).
Ensure the remote is plugged in.
Note: The machine will not operate without the remote and will stop if it is accidentally pulled out or
the cable severed.

To set the machine up to install cable it will be necessary to:
Select the appropriate torque setting for the cable being installed, if in doubt start with the low torque setting.
Fit the tube into which the cable is to be installed into the air box and tube clamp.
Fit the cable through the machine.
Connect the air supply to the machine.
Connect the electrical power input to the machine.