General Machine Products 89300 AirStream Cable Blowing Machine User Manual

Page 7

Advertising
background image

Page 7 of 44

2.0 CRITICAL POINTS THAT DRAMATICALLY AFFECT THE
OPERATION OF THE CABLE BLOWING MACHINE


►

PRESSURE ON THE CABLE (POSITION OF THE CLOSE ARM ASSY) SHOULD BE SET AS

PER THE INSTRUCTIONS

►

BELTS TO BE CLOSED AT ALL TIMES WHEN CABLE IS INSTALLED INTO MACHINE.

►

CORD SEALS IN AIR CHAMBER IN GOOD CONDITION AND CORRECTLY INSTALLED TO

PROVIDE GOOD SEALING.

►

CORRECT CABLE SEAL INSTALLED.

►

TUBE FULLY CONNECTED AND PRESSURE-TESTED.

►

TUBE AND CONNECTING FITTINGS ARE SUITABLE FOR OPERATING AT 15 BAR AIR

PRESSURE.

►

TUBE CLAMP SECURELY TIGHTENED.

►

COMPRESSOR CAPACITY 15 BAR AND SUITABLE FOR SIZE OF TUBE BEING USED.

►

CABLE DRUM MUST BE LOCATED DIRECTLY BEHIND AND IN LINE WITH THE BLOWING

MACHINE.

►

AIR CHAMBER, DRIVE BELTS AND PULLEYS, CABLE GUIDES, MUST BE CLEAN AND

FREE FROM DEBRIS, SLUDGE, DIRT, WATER AND LUBRICANT.

►

THE CABLE MUST BE HAND GUIDED INTO THE BLOWING MACHINE THROUGH A DRY

CLEAN CLOTH BY THE OPERATOR WEARING WORK GLOVES.

►

ENSURE THE COMPRESSED AIR SUPPLY IS NOT APPLIED TO THE CABLE UNTIL

APPROXIMATELY 150 FEET OF CABLE HAS BEEN INSTALLED OR THE MOTOR BEGINS
TO LABOR.




Advertising