INFICON PGD400 Pirani Gauge Display User Manual
Page 10
Advertising
10
tinb14e1 (2009-07)
Measurement values
Measurement range
(air, O
2
, CO, N
2
)
5×10
-4
… 1000 mbar
(+1.9 … +10.0 VDC)
(
→ [1])
Measurement error
Gain error
Offset error
≤0.02% FSr
≤0.05% FSr
Measurement rate
30 / s
Display rate
50 / s
Filter time constant
150 ms (f
g
= 1 Hz)
Pressure units
mbar, Pa, Torr
Gauge supply
Voltage
+24 VDC
±5%
Current 750
mA
Power consumption
18 W
Fuse protection
900 mA with PTC element, self-
resetting after turning the
PGD400 off or disconnecting the
gauge
Switching function
Number 1
Reaction delay
≤10 ms if switching threshold
close to measurement value (for
larger differences consider filter
time constant).
Adjustment range
1×10
-3
… 500 mbar
Hysteresis
≥
10% of measurement value