2 identity object – INFICON PSG55x ATM to Medium Vacuum Gauge (DeviceNet) User Manual

Page 12

Advertising
background image

12

tira58e1-a (2012-03) PxG5xx.cp

Class Code 01

h

= 01

d

This object provides identification of and general information about the device.

Attribute ID Access rule

Name

DeviceNet
data type

Description of attribute

Semantics of values

1

Get

Revision

UINT

Revision of this object.

The current value assigned to this
attribute is one (01). If updates that
require an increase in this value are
made, then the value of this attribute
increases by one.

2

Get

Max instance UINT

Maximum instance number of
an object currently created in
this class level of the device.

The largest Instance number of a
created object at this class hierarchy
level.



Attribute ID Access rule

NV/V Name

DeviceNet data type

Description of attribute

1

Get

NV

Vendor ID

UINT

Manufacturer identification
Value: 633 (INFICON AG) (default)

2 Get

NV

Device

type

UINT

1C

h

= Vacuum pressure gauge

3 Get

NV

Product

code

UINT

→ "Semantics" section below

4

Get

NV

Revision

STRUCT

Major Revision 1; Minor Revision 1

5 Get

NV

Status

WORD

6 Get

NV

Serial

number

UDINT

7

Get

NV

Product name

SHORT STRING

→ "Semantics" section below

100 Get

NV

Software

Revision

Level

SHORT STRING

Revision of the DeviceNet board software
(major number) (minor number)
(development number)
e.g. 01 02 00


Relationship between product code and product name.

Product code Sensor type

Product name

19

CDG, Pirani

PCG550, PCG552, PCG554

20

CDG, Pirani, ATM PCG550, PCG552, PCG554

21

Pirani

PSG550, PSG552, PSG554


Service Code Name

Description

5 (05

h

)

Reset

0 = last installation,
1 = default installation (factory reset)

14 (0E

h

) Get_Attribute_Single



4.2 Identity Object

4.2.1 Class Attributes

4.2.2 Instance Attributes

4.2.3 Semantics

4.2.4 Services

Advertising