Over-Temperature Input (Normally Closed)

• Terminate (OVERTEMP INPUT (NORMALLY CLOSED))

on J18 connector.

• Disables all dimmer outputs when contact/switch is opened.

• Controlled via a maintained contact/switch to +12V.

• Connects to OEM wiring in Strand CD80

®

Supervisor (SV) racks

via the power connector.

Over-Temperature Input (Normally Open) (TS1)

• Terminate (OVERTEMP INPUT (NORMALLY OPEN) (TS1))

on J18 connector.

• Disables all dimmer outputs when contact/switch is closed.

• Controlled via a maintained contact/switch to low-voltage

common (COMMON).

• Connects to OEM wiring in Strand CD80

®

Supervisor (SV) racks

via the power connector.

• Optionally connects to OEM wiring in Strand CD80

®

AMX

or Advanced Electronic (AE) racks.

Connect to TS1 located on the upper left-hand side of the dimmer rack.

Connect COM, also located on the upper left-hand side of the dimmer

rack, to COMMON on the CD-3000 Backplane.

Fire Alarm Input (Normally Open)

• Terminate on J18 connector.

• Triggers selected channels to turn on when contact/switch is closed.

• Controlled via a maintained contact/switch to low-voltage common (COM).

• Programmed in the “F-ALARM” menu. See page 29 for details.

Security Alarm Input (Normally Open)

• Terminate on J18 connector.

• Triggers selected channels to cycle on and off at a 1 Hertz rate when

contact/switch is closed.

• Controlled via a maintained contact/switch to low-voltage common (COM).

• Programmed in the “S-ALARM” menu. See page 28 for details.

Auxiliary Input (Normally Open)

• Terminate on J18 connector.

• Triggers 1 of 20 presets when contact/switch is closed.

• Controlled via a maintained contact/switch to low-voltage common (COM).

• Programmed in the “AUX IN” menu. See page 28 for details.

Open Collector Output

• Terminate on J18 connector.

• Sink up to 100mA.

• Trigger Solid State Relays (SSR) or other external devices.

• Controlled via DMX and/or Analog Input 4.

• Programmed in the “OC MODE” menu. See page 28 for details.